Showing posts with label a.o. smith water heater. Show all posts
Showing posts with label a.o. smith water heater. Show all posts

Tuesday, 20 March 2018

Tips for Replacing Carrier Condenser Fan Motor HC39GE238 Effectively



A carrier condenser fan motor HC39GE238 plays a vital role in the performance of an HVAC system. Its function is to cool the hot, refrigerant gas to a cool liquid. Most of the carrier condenser fan motors today are a single speed although some ultra efficient split systems now have an ECM condensing fan motor. If the motor is not spinning the fan blade on your heat pump or air conditioner condensing unit, it may not be an issue with the motor itself. There could be a minor electrical issue involving a low ambient control, capacitor or a relay. If your system is turned off, you may attempt to spin the condenser fan blade. If the blade is tight and will not turn, the motor has locked and will need to be replaced. The many working gears and windings within the motor are under almost constant use and like any other component on a condensing unit are exposed to the elements. 

As we are in the heart of air conditioner season, you may find yourself dealing with an expired carrier condenser fan motor HC39GE238. Fortunately, this is a repair that can be done by non-professionals. Start by confirming the issue is in fact a motor in need of replacement. Begin by turning off the power to the A.C unit. Then manually try spinning the fan blade. If the blade doesn’t turn freely, the motor is in need of replacement.

What to Check before Opting for Installing Carrier Condenser Fan Motor HC39GE238?


Most air conditioner models will allow you to replace the expired part with a carrier condenser fan motor. But in using a substitution, certain criteria must be met. So before purchasing a replacement make sure you taken notes from the original unit on the following:


  •        Motor diameter in inches
  •          Horsepower rating-be aware the some A.C. units have more than one
  •         Operating voltage-units can range from 115-460
  •          Motor shaft size in inches
  •         RPM speed
  •          Direction of Rotation
  •          Mounting (not all units are mounted in the same way)


This is not exactly a DIY project unless you have the technical expertise to do it. Do not attempt to perform this service unless you are a qualified professional and have all the proper tools and safety equipment. If in doubt, then contact a reputable local HVAC company that can install your new carrier condenser fan motor HC39GE238. 

Process to Replace the Old One with New Carrier Condenser Fan Motor HC39GE238

Once you are ready to install your carrier condenser fan motor HC39GE238, start by shutting down all electric supply to the AC unit via the breaker box for safety precautions; it’s very important that you don’t skip this step. Before removing anything, take note of the motor’s wiring (what colors of wiring, how they are connected, etc.). The fan and motor can now be dismantled, which is generally done by removing bolts on the band that secures the motor. In some units, these bolts are actually attached directly to the motor. Now remove the fan blade. Before doing so, take note of the blade’s position on the shaft. Loosen the screws, and remove the blade from the motor shaft by twisting and tugging. Once the old unit is out, to install the new one, simply reverse the process described above. Be especially careful when reinstalling the fan blade. Make sure the blade is centered in the fan motor’s opening.

But you are not quite done. Every time you replace a carrier condenser fan motor HC39GE238, you should also replace the AC’s run capacitor, which is a cylinder-shaped device that helps to start or run motors. To replace it, again take down all technical data on the unit, and note wiring colors and positions before removing it with a screw driver. As with the fan condenser motor, your run capacitor replacement selection is based on its technical data, not shape or size.

To install the new carrier condenser fan motor HC39GE238, reverse its removal process, but before replacing any covering and reactivating the AC, go stand outside by the AC and wait for the contractor to come on. When it does, it will buzz or hum and may take several minutes to do so. After hearing the contractor, replace the covering and restore power. Test the AC to make sure fan and cool aiproduction are normal before resume using it.

Monday, 26 February 2018

Why and How to Use Honeywell Fan Timer Control Board for Cooling Electronic Equipment?





Interest has been growing in integrated circuits for controlling the speed of cooling electronic components. Compact electrical fans are cheap and have been used for cooling electronic equipment for more than half a century. However in recent years, the technology of using Honeywell fan timer control board has evolved significantly. Here, you’ll find the detail description of why this evolution has taken place and will suggest some useful approaches for the designer.

Heat Generation and Removal:

The trend in electronics, particularly consumer electronics, is towards smaller products with enhanced combinations of features. Consequently, lots of electronic components are being shoehorned into very small form factors. Besides significantly smaller and still decreasing size, the amount of heat they must dissipate doesn’t decrease. This heat needs to be removed quietly and efficiently. Use of Honeywell fan timer control board provides a quietest way to remove heat through passive components. 

Introduction of Honeywell fan timer control board to the system is a very important consideration if power is to be supplied via a battery source. 

Speed Control:

One way to answer some of the objectionable questions to use Honeywell fan timer control board is to look for the advantages it offers; which are:


  •          Running Honeywell fan timer control board in the system reduces the noise it emits
  •          Running Honeywell fan timer control board can reduce the power it consumers
  •          Running Honeywell fan timer control board in the system can increase the system’s reliability and lifetime



Besides eliminating the need for noisy pulse stretching and the communication noise associated with low-frequency, the Honeywell fan timer control board has a much wider control range than linear control. Keeping the high-frequency near, the Honeywell fan timer control board can run at speeds as low as 10% of full speed while normally you get a minimum of 50% full speed using linear control board. Finally, running the Honeywell fan timer control board also improves its lifetime, increasing system’s reliability gradually.


Thus, if you are in search of Honeywell fan timer control board; visit acpartsdistributors.com today. Or contact the specialists to install it in your system directly.

Thursday, 14 September 2017

Home Air Conditioning Parts You Should Know About




The tangible parts of your home air conditioning system give you a way to distribute air and regulate the temperatures in your home, but they have nothing to do with producing hot/cool air. You can see the grilles from inside your home, and you probably adjust the thermostat from time to time, but there is much more to your system than you can see. The home air conditioning parts that are involved in producing heat or cool air for your home include these: 


  •          Heat exchanger
  •          Furnace
  •          Blower
  •          Exhaust
  •          Evaporator



The furnace is where all of the action takes place, concealing the working components of your heating system. In a large metal carton located in your attic, basement or closet, your furnace serves as a central command post that directs and coordinates the system’s components. A furnace serves many purposes for industry, but the function of a forced air unit in your home is convert cold air into warm or vice versa by using gas or electricity. The heat exchanger inside the furnace warms air when it is needed, using a burner in gas systems or coils in those that use electric power. When air reaches the proper temperature, the blower (one of the home air conditioning parts in the system) sends warm air into your duct system for distribution to rooms through vent grilles. The exhaust system performs a vital function of releasing gases into the outdoors, and draft hoods allow the safe release of carbon monoxide. Maintaining your home air conditioning parts of the system can extend its lifetime.

In most of the home air conditioning system, the evaporator is located inside the top of the system and made of many coils. Refrigerant enters the evaporator from the condenser in its cool, liquid form. Once the liquid refrigerant enters the evaporator, it is met with low pressure. Because of this low pressure, the liquid refrigerant turns into gas then it absorbs heat from the air surrounding it. This absorption of heat; therefore, cools the inside of your home. From here, the gas refrigerant returns to the condenser to repeat its cycle. 

Keeping these home air conditioning parts well-maintained will don’t allow you to spent high bucks on the repair section or don’t think of replacing the total home air conditioning system. Time-to-time maintenance is all these home air conditioning parts need for better performance.

Industries Becoming More Comfortable with Robertshaw Gas Valves




Valves have become an important part of the industry usages. Ranging from highly productive industries to small-scale industries and from nuclear plants to thermal power plants; you will find gas valves performing their basic functions almost everywhere. The entire plumbing systems are dependent on gas valves and therefore it is critical to select the right gas valves to save costs and most important of all to save lives.

When it comes to choosing gas valves, there are many companies and suppliers you can count on. In fact, the gas valve manufacturing companies in the USA supply over 35% of global gas valves’ demands. Dedication to provide quality products and high regards for safety are the main reasons for this phenomenal success. 

Few Reasons Why You Should Purchase Robertshaw Gas Valves 

Robertshaw Gas Valves are Safest: USA based companies design and monitor gas valves to curtail the impact of chemicals on the safety and health of humans and the environment as well. This makes Robertshaw gas valves the safest and reliable product among other gas valves around.

Highly Dependable: The complete range of Robertshaw gas valves are certified from the government authorities and thus companies carrying these gas valves are considered most reliable and dependable.
Superior Product: Being designed by the most trusted brand, Robertshaw gas valves guarantee superior operation and stability in body design. Robertshaw gas valves are highly resistant to corrosion, highly durable and offer a true value for money.

The Robertshaw gas valves surpass the ISO standard to ensure quality without compromise. The Robertshaw gas valves fulfill all requirements and daily needs of the industries, be it used anywhere.
Need authentic Robertshaw gas valves? Contact AC Parts Distributors right away!